Home > Press > Deben reports on a new publication from scientists at La Trobe University in Australia where their CT500 stage is used in micro scanning tomography experiments to better understand ceramic matrix composites under load
![]() |
A Deben CT500 loading stage mounted in a ZEISS Xradia XCT200 micro computed tomography system as used in the La Trobe Institute for Molecular Science, [image source: http://www.latrobe.edu.au/surface/capabilities/x-ray-micro-computed-tomography-xct] |
Abstract:
Deben, a leading provider of in-situ testing stages together with innovative accessories and components for electron microscopy, reports on a publication in Microscopy & Microanalysis from the La Trobe Institute for Molecular Science. This shows a Deben CT500 tensile and compression stage being used in conjunction with a ZEISS Xradia Micro XCT system to enable a better understanding of ceramic matrix composites under various tensile bending loads.
Dr Benedicta Arhatari is X-ray Tomography Laboratory Manager at the ARC Centre of Excellence in Advanced Molecular Imaging at the La Trobe Institute for Molecular Science. Her responsibilities include the day-to-day operation of the x-ray source, the construction of imaging experiments and the use of appropriate position-sensitive x-ray detectors while her research focus is on the development and testing of the theory for optimising phase imaging performance.
The Laboratory uses a ZEISS Xradia µXCT system which is configured with a fixed X-ray source that passes a cone of X-rays through the specimen. The transmitted X-rays are then captured by an imaging detector. Projections through the sample are collected by rotating the specimen from -90° to +90°. These projected images are later combined and reconstructed using algorithms to build a 3D image of the sample. Samples may be studied under tension or compression using a Deben CT500 in situ stage configured with 4-point bending clamps and controlled from the comprehensive, integrated MICROTEST tensile stage control software which offers a wide range of control functions and a live display of load versus extension.
Dr Arhatari, with co-workers from the University and the Defence Science and Technology Group in Melbourne, has recently published a paper entitled “Local Structural Damage Evaluation of a C/C-SiC Ceramic Matrix Composite.”1 It reports on the importance of the local distribution and concentration of SiC and its effect in reducing the toughness of the ceramic matrix composite using data gathered from the Deben-Xradia combination. The images in the paper show very detailed visualisation of the crack propagation process with the three-dimensional capability enabling clear difference in crack behaviour depending on the plane being studied.
The authors concluded that the key finding from the present study (combining radiography, µXCT and four-point bend testing) showed that the process of fibre pull-out in C/C–SiC CMCs can be linked to the material toughness. Furthermore, the present study combining load testing and X-ray microscopy highlights how important the local variations in these parameters can be in determining the overall strength of these complex composite materials.
The Deben CT500 in situ testing stage is versatile and adaptable. With a weight of less than 1.0 kg, it is suitable for mounting within the most common mid-range µXCT systems such as the Nikon XTH-225, ZEISS/Xradia Versa and GE v|tome|x as well as the “nano” systems such as the ZEISS/Xradia XCT-200 and GE Nanotom S. To obtain full details of the Deben applications and product portfolio, please visit www.deben.co.uk.
Reference
1 Local Structural Damage Evaluation of a C/C-SiC Ceramic Matrix Composite, B D Arhatari et al, Microsc. Microanal. 23(3):518-526, (2017), doi:10.1017/S1431927617000459
####
About Deben
Deben are a UK precision engineering company specialising in the field of in-situ tensile testing, motion control and specimen cooling for microscopy applications. Established in 1986 and named after a Suffolk river, Deben now operate from a large, modern business unit in Woolpit near Bury St. Edmunds in Suffolk. The product groups are motor control systems, in-situ micro-tensile stages, Peltier heating & cooling stages, detectors for SEMs and electro-static beam blankers. The company also makes custom and OEM versions of these products to specifically meet customer requirements.
Deben provide consultancy, design and prototype manufacturing services. In house facilities include SolidWorks and SolidEdge 3D CAD and COSMOS finite element analysis software, CNC machining, electronics design and manufacture and software design using Visual C++, Microsoft.net and DirectX. Utilising these resources and experience, Deben manufacture products for OEMs and end users in the UK and overseas.
Deben UK Ltd. is a subsidiary company of UK based Judges Scientific plc. For details on Deben and all its products & solutions, visit www.deben.co.uk.
For more information, please click here
Contacts:
Deben UK Limited
Brickfields Business Park
Old Stowmarket Road
Woolpit, Bury St Edmunds
Suffolk IP30 9QS, UK
T +44 (0)1359 244870
www.deben.co.uk
Talking Science Limited
39 de Bohun Court
Saffron Walden
Essex CB10 2BA
T +44(0)1799 521881
M +44(0)7843 012997
www.talking-science.com
Copyright © Deben
If you have a comment, please Contact us.Issuers of news releases, not 7th Wave, Inc. or Nanotechnology Now, are solely responsible for the accuracy of the content.
Related News Press |
News and information
Closing the gaps — MXene-coating filters can enhance performance and reusability February 28th, 2025
Rice researchers harness gravity to create low-cost device for rapid cell analysis February 28th, 2025
Imaging
Turning up the signal November 8th, 2024
New discovery aims to improve the design of microelectronic devices September 13th, 2024
Quantum researchers cause controlled ‘wobble’ in the nucleus of a single atom September 13th, 2024
Discoveries
Closing the gaps — MXene-coating filters can enhance performance and reusability February 28th, 2025
Rice researchers harness gravity to create low-cost device for rapid cell analysis February 28th, 2025
Announcements
Closing the gaps — MXene-coating filters can enhance performance and reusability February 28th, 2025
Rice researchers harness gravity to create low-cost device for rapid cell analysis February 28th, 2025
Interviews/Book Reviews/Essays/Reports/Podcasts/Journals/White papers/Posters
Leading the charge to better batteries February 28th, 2025
Quantum interference in molecule-surface collisions February 28th, 2025
New ocelot chip makes strides in quantum computing: Based on "cat qubits," the technology provides a new way to reduce quantum errors February 28th, 2025
Tools
Rice researchers harness gravity to create low-cost device for rapid cell analysis February 28th, 2025
New 2D multifractal tools delve into Pollock's expressionism January 17th, 2025
Turning up the signal November 8th, 2024
![]() |
||
![]() |
||
The latest news from around the world, FREE | ||
![]() |
![]() |
||
Premium Products | ||
![]() |
||
Only the news you want to read!
Learn More |
||
![]() |
||
Full-service, expert consulting
Learn More |
||
![]() |