Home > Press > Novel electron tomography software using multi-GPUs by Digisens
Abstract:
More than only cross-correlation to align a raw tilt-series without fiducials, 3D reconstruction with iterative algorithms (SART, SIRT, OS-SART) using multi-GPUs, intuitive 3D/2D visualisation: DigiECT positions itself as a revolutionary alternative compared to existing commercial and free software.
New-generation electron tomography software commercially available
Shortly after its commercial release in May 2010, Digisens is pleased to announce the growing success of its novel electron tomography software DigiECT, which is the result of a two-year fruitful collaboration with Dr. Sergio Marco, Research Director Inserm U759, Institut Curie, Orsay, France. Moreover, DigiECT has been recently adopted by IPCMS-CNRS, a french nanotechnology institute based in Strasbourg, along with two other well-renowned research centers.
Using a TEM (Transmission Electron Microscope), electron tomography is an imaging technique for advanced 3D nanocharacterization in Life Sciences as well as Materials Sciences.
Requiring only a raw tilt-series at input, DigiECT is fully compliant with all TEM brands, all image acquisition modes (BF-TEM, BF-S/TEM, DF-S/TEM or EFTEM) and schemes (linear, Saxton or user-defined). Its core philosophy relies in allowing reduced 3D reconstruction times, targeted to better image quality using iterative algorithms - best suited to cope with the missing wedge - while minimising manual interventions to save time and prevent human erros.
"We were using free software for 3D reconstruction and it was really time-consuming, even on the GPU. The alignment step has often to be corrected manually. With our recent investment in DigiECT, way faster 3D reconstruction speeds will bring us more time to achieve high-quality results" states Dr. Ovidiu Ersen, responsible of the electron tomography facility at IPCMS-CNRS.
Marker-less alignment, multi-GPUs 3D reconstruction and ergonomic visualisation
The primary step consists in automatically aligning the images without markers such as gold beads then numerically determining the location of the tilt axis in 3D (x, y, z). "This process is more than a rudimentary cross-correlation step, in order to avoid any drifts which are likely to occur along the stack: we basically track virtual markers" explains Dr. Jean-Pierre Bruandet, Digisens' Chief Technical Officer.
As everyone knows, perfect alignment is mandarory prior to the subsequent 3D reconstruction phase. As for this, unique advantages of DigiECT's 3D reconstruction module are numerous.
With Digisens' exclusive multi-GPUs technology, DigiECT is first able to make use - at the same time - of several GPU boards (Graphical Processing Units) mounted in parallel, to split and resolve the 3D reconstruction process with unparalleled speeds. For instance, a 2048 x 2048 x 512 voxels volume (8.0 GB) is resolved in 31.2 seconds per iteration (SIRT) - including I/O - using 8 GPUs (Nvidia C2050). "With the recent advent of high-resolution cameras of 16 megapixels and beyond, we now encounter bottlenecks during the 3D reconstruction process. DigiECT overcomes this issue, offering incredible processing speeds" explains Dr. Marco.
Second, users can reach optimal convergence of the 3D reconstruction since they can adjust if desired the convergence speed, a major parameter even more important than the number of iterations when using iterative algorithms. Third, DigiECT proposes to 3D reconstruct a volume using OS-SART algorithm (Ordered-Subset Simultaneous Algebraic Reconstruction Technique) to get the best possible balance between the resolution of SART and noise robustness of SIRT.
Following both alignment and 3D reconstruction stages, end-users benefit from an intuitive, user-friendly visualisation tool, featuring uppermost quality volume and isosurface rendering, high-resolution oriented cut planes extraction, advanced measurements, certified surface extraction and seamless data import or export in numerous file formats.
For more details on DigiECT browse www.digisens.fr not to mention that Digisens' team will be pleased to answer your questions at +33 (0) 686 615 513 or by email at
####
About Digisens
Incroporated in 2002, Digisens is a high-tech software editor located in the French Alps between Geneva and Grenoble with world-renowned customers in research, industry and healthcare in Europe and North America. Thanks to its outstanding innovation capabilities and overall mastering of multi-GPUs programming, Digisens develops high value-added 3D-imaging software solutions for X-ray computed microtomography and nanotomography (DigiXCT & DigiHCT) as well as electron tomography (DigiECT).
For more information, please click here
Contacts:
Maxime Wiot
Business Development Manager
Tel: +33 (0) 686 615 513
Copyright © Digisens
If you have a comment, please Contact us.Issuers of news releases, not 7th Wave, Inc. or Nanotechnology Now, are solely responsible for the accuracy of the content.
Related News Press |
News and information
Beyond wires: Bubble technology powers next-generation electronics:New laser-based bubble printing technique creates ultra-flexible liquid metal circuits November 8th, 2024
Nanoparticle bursts over the Amazon rainforest: Rainfall induces bursts of natural nanoparticles that can form clouds and further precipitation over the Amazon rainforest November 8th, 2024
Nanotechnology: Flexible biosensors with modular design November 8th, 2024
Exosomes: A potential biomarker and therapeutic target in diabetic cardiomyopathy November 8th, 2024
Software
Visualizing nanoscale structures in real time: Open-source software enables researchers to see materials in 3D while they're still on the electron microscope August 19th, 2022
Luisier wins SNSF Advanced Grant to develop simulation tools for nanoscale devices July 8th, 2022
Oxford Instruments’ Atomfab® system is production-qualified at a market-leading GaN power electronics device manufacturer December 17th, 2021
Announcements
Nanotechnology: Flexible biosensors with modular design November 8th, 2024
Exosomes: A potential biomarker and therapeutic target in diabetic cardiomyopathy November 8th, 2024
Turning up the signal November 8th, 2024
Nanofibrous metal oxide semiconductor for sensory face November 8th, 2024
Tools
Turning up the signal November 8th, 2024
Quantum researchers cause controlled ‘wobble’ in the nucleus of a single atom September 13th, 2024
Faster than one pixel at a time – new imaging method for neutral atomic beam microscopes developed by Swansea researchers August 16th, 2024
The latest news from around the world, FREE | ||
Premium Products | ||
Only the news you want to read!
Learn More |
||
Full-service, expert consulting
Learn More |
||