Nanotechnology Now

Our NanoNews Digest Sponsors
Heifer International



Home > Nanotechnology Columns > Park Systems > True Sample Topography Acquired by Low-Noise Z Position Sensor

Sue. J. Kim
Global Marketing Manager
Park Systems Corp.

Abstract:
It has been used not only in the academic instrumentation, but in the commercial AFM products because of its simplicity in structure, and its possibility to move continuously in the nanometer scale. However, it has also been associated with hysteresis and creep errors that prevented conventional AFMs from providing an accurate topography of a sample. Park has developed Park NX10 featuring a very low noise Z sensor that enables a true topography AFM scanning of a sample.

March 28th, 2012

True Sample Topography Acquired by Low-Noise Z Position Sensor

Piezoelectric material has been widely used as the actuator of the positioning scanner in an atomic force microscope (AFM) since the invention of the AFM1.
Click here for full application note

It has been used not only in the academic instrumentation, but in the commercial AFM products because of its simplicity in structure, and its possibility to move continuously in the nanometer scale. However, it has also been associated with hysteresis and creep errors that prevented conventional AFMs from providing an accurate topography of a sample. Park has developed Park NX10 featuring a very low noise Z sensor that enables a true topography AFM scanning of a sample.
In the early stage of the AFM development, the open-loop scanning method was used to control the scanner. Here, the scanner moves as the piezoelectric actuator expands and contracts in response to the calibrated applied voltage. This was soon replaced by the closed-loop scanning method2 because the open-loop method introduced nonlinear errors of hysteresis and creep errors to the AFM image. The closed-loop scanning method employed additional position detectors to each axis of the scanner, and applied voltage to the scanner to correct and keep its position at the desired location. Subsequently, the closed-loop scanning method became indispensible for the accurate scanner control. However, the closed loop feedback was limited to the X and Y directions of a sample surface and not on Z (height) direction due to the significant noise level on its Z position detector.

Bookmark:
Delicious Digg Newsvine Google Yahoo Reddit Magnoliacom Furl Facebook

NanoNews-Digest
The latest news from around the world, FREE




  Premium Products
NanoNews-Custom
Only the news you want to read!
 Learn More
NanoStrategies
Full-service, expert consulting
 Learn More











ASP
Nanotechnology Now Featured Books




NNN

The Hunger Project