During last 20-30 years the instruments that explore or probe the surface of ultra-small samples have steadily proliferated. Physicists, chemists, and molecular biologists working in nanoscience have had to familiarize themselves with microscopes that use thermal, magnetic, capacitive, and electrochemical properties. What is next for this amazing family of SPM?
July 10th, 2010
Next step in nanotechnology instrumentation: Atomic Force Microscopy and X-Ray Fluorescence Analysis Integration
Introduction
Nanotechnology has received an enormous amount of attention in the past several years, but not much data exist to help make decisions about integration of various nanotechnologies into strategic planning. The most vulnerable and underdeveloped area in this industry is the instrumentation.
The tools and instrumentation for nanotechnology: processes, products, and applications are the means which allow the work of nanotechnology. Every aspect of basic nanoscale science as well as commercial production of nanotechnologies are highly related to the capacity of instruments and tools to measure, sense, fabricate, and manipulate nanosize particles. Thus the nanotechnology tools and instruments represent the hardware, software, and supplies employed to measure and manipulate structures on the level of nanosize. They include microscopes, probes, lithography systems, manipulation and fabrication systems, software, and other accessories.
The history of nanoscale instrumentation started on the days in 1981 when the scientists at IBM Research announced the invention of the scanning tunneling microscope (STM) and later on - its successor - the scanning probe microscope (SPM) and its useful variation - the atomic force microscope (AFM).
Nanotechnology: new generation of instruments
During last 20-30 years the instruments that explore or probe the surface of ultra-small samples have steadily proliferated. Physicists, chemists, and molecular biologists working in nanoscience have had to familiarize themselves with microscopes that use thermal, magnetic, capacitive, and electrochemical properties. What is next for this amazing family of SPM?
There are various approaches to the nanotechnology instrumentation. Some of the most successful designs consider devices with broad functionality to be one of the most promising directions in the equipment development. However there is a distinction between technology and science in any size range, especially in nanoscale. It is obvious that the researchers at the leading edge of nanoscience expect the devices with broad and flexible functionality whereas those with routine needs in production may benefit from using specialized user-friendly instruments.
The difficulty in progressing from experimentation to technology consists not only in ability to build reproducible nanoscale structures, but in connecting a nanodevice to controls. The probe or the tip of a SPM or AFM can be likened to a finger: it can touch, push, drag, but not much else. For the nanoscale that is not enough. Nanotechnology ought to go to more complicated schemes. The next generation of nanoinstruments has to combine the functions of several devices.
Thus, the major challenge here does not lie only in operating those instruments, but in understanding what is being observed with them. Therefore the operator might be required to be familiar with chemistry, surface science, electronic structure, and possibly many other things.
At the same time, speaking about nanotechnology instruments we mean not only microscopes and their derivatives. The necessity to obtain information about the features other than the size of the object, such as elemental properties, made scientists to create a new generation of specialized and flexible devices for research with improved resolution, chemical specification, sampling volume, data acquisition speed, sensitivity, detection limits, etc. These new instruments at times surprise the scientists by utilizing the techniques that yet recently none would consider to be possibly combined.
Numerous examples have been shown recently by various scientific and business groups. Some of them are of great importance. The capabilities of a fluorescence resonance energy transfer technique that can measure distances on the 2-8-nm scale were combined with optical trapping to generate new quantitative data . Near-field optical effects on the nanoscale have stimulated the development of apertureless vibrational spectroscopy and imaging with ultrahigh spatial resolution, which, for instance, was demonstrated on Raman spectra of the bundles of single-walled carbon nanotubes (SWCNTs), recorded with a scanning near-field optical spectrometer using both atomic force (AF) and shear force (SF) feedback lock-in regulation. It is shown in particular that this method ensures a subwavelength spatial resolution of about 50 nm and demonstrates Raman scattering enhancement as high as 104. The scanning near-field optical microscope (SNOM) which offers dramatically improved resolution over standard optical tools was combined with an AFM in order to yield imaging and force measurement . Recently, new complex instruments that utilize various fluorescence spectroscopic techniques in X-ray range have been introduced .
Atomic Force Microscopy (AFM)
AFM or scanning force microscope (SFM) is a type of a scanning probe microscope with demonstrated resolution of a nanometer fraction that is more than 1000 times better than the optical diffraction limit. The Atomic Force Microscope was developed to overcome a basic drawback of its predecessors that could only image conducting or semiconducting surfaces. AFM gathers information by "feeling" the surface with a mechanical probe. Nowadays AFM represents the SPM technique in most common use, and its popularity stems primarily from the wide range of objects for which it is suitable to obtain that high resolution of imaging (see examples here: http://www.ntmdt.com/spm-principles ). It has been evolved from a simple surface topography profiler to a diverse microscopy and microanalysis system. Not only it gives a variety of images of nanoscale structures, but it can also be used as a manipulator of those structures. Thus, AFM is an important microscopy tool because of its low cost, high resolution, and versatility. Due to its capability of measuring nanometer scale images of insulating surfaces with little or none sample preparation, AFM has a vast number of applications in many areas of science and technology.
Micro X-ray fluorescence spectroscopy
X-ray fluorescence (XRF) represents the emission of characteristic "secondary" (or fluorescent) X-rays from a material that is excited by high-energy X-rays or gamma rays bombarding. This phenomenon is widely used for elemental and chemical analysis. In the development of new analytical methods, there is a trend to use smaller quantities of specimens due to scarcity of the sample, limited collection times, and the need for speed analysis. The majority of nanotechnology researchers currently use specimen quantities of less than 100 mg. Considerations of cost and portability of the equipment are also of a great importance.
Micro X-ray fluorescence analysis (MXRF) is an elemental analysis technique which allows examination of tiny sample areas. It was shown that examination of bulk materials is feasible using a micro beam XRF spectrometer to obtain effective subsample masses substantially below 1 ìg . Like conventional XRF instrumentation, MXRF employs direct X-ray excitation to induce characteristic X-ray fluorescence emission from the sample for elemental analysis. Unlike conventional XRF, which has a typical spatial resolution ranging in diameter from several hundred micrometers up to several millimeters, MXRF uses X-ray optics to limit the incident beam size to a small spot on the sample surface so that tiny features on the sample can be analyzed. Traditional MXRF instrumentation uses a simple pinhole aperture to restrict the incident beam size on the sample surface. Only the X-rays coaxial with the hole pass through the aperture. Unfortunately, this method also screens out most of the X-ray radiation emitted by the source, which results in a very small radiation flow on the sample and adversely affects the method's sensitivity of trace elemental analysis. To increase the sensitivity and precision of mentioned techniques special optical systems have been developed.
Optical systems for MXRF
X-ray optics is the branch of special optics which operates in X-ray range of electromagnetic radiation. The optics for Roentgen range is quite different though. There are a variety of techniques used to transmit X-ray photons to the appropriate location on the detector. Due to absence of a "transparent" material for X-rays with suitable refractive index, X-ray optics use effects of reflection, diffraction, or interference. The most advanced of them are polycapillary and double curved crystal focusing optics, which offer alternative means to generate small focal spots with high radiation density on the sample surface. There are numerous configurations in MXRF optical schemes design. Some of them that seem to be the most common are provided in Figures 1-2.
Capillary/polycapillary optical systems (see, for instance ) utilize total external reflection to bring X-rays to a common focus. Broadly used polycapillary focusing X-ray optics offers successful means to generate small focal spots with high X-ray radiation density on the sample surface. Additionally, this optics overcomes the limitation of inverse square dependence of intensity from the distance from the source. This enables to employ the small size and low power MXRF systems in design of remote or portable instruments.